Product Details:
Model Name/Number | Bio JVA |
Brand | Bio Research |
Usage/Application | Laboratory Use |
Frequency Means | 51 - 100 Hz |
Maximum input amplitude | 0.0 to 0.5 Kilo Pascals (1000 N/m2) |
Time of a single recording | 10 seconds - 3.0 minutes (180 seconds) |
JVA System input amplitude resolution | 0.2 Pascal (8 bit ISA A) |
JVA System Bandpass | 25 Hz to 10,000Hz |
Being a trustworthy name in the industry, we are able to offer a superior quality array of Bio Jva Biometric Instrument to our patrons.
Product Features:
Product Details:
Usage/Application | Hospital |
Model Name/Number | Bio EMG III |
Brand | Bio Research |
Type Of Equipment | Bio Metric Instrument to Record Muscle Activity |
Range | 0 to 2000 Microvolts |
Offset Range | -0.7 volt to +0.7 volt DC |
Bandwidth | 30 to 1000 Hertz |
Resolution of AD converter | 0.5 microvolt |
Maximum Peak Voltage | 3500 Volts |
Impedance | 108 Ohms |
Common Mode Rejection Ratio | Greater than 130 dB at 60 Hertz |
Leakage Current | Less Than 1.0 Microampere |
Being a trustworthy name in the industry, we are able to offer a superior quality array of Bio EMG III Biometric Instrument to our patrons.
Product Features:
Product Details:
Usage/Application | Hospital |
Model Name/Number | Quadra Tens |
Brand | Bio Research |
Power Source | Battery Operated |
Balance Range | 1/3 to 3/1 |
Frequency Range | 60 pulses/min |
Amplitude Range | 0.7mA to 80mA (peak to peak) |
Pulse Shape | Biphasic, Variable Symmetry with Zero Net DC Component |
Pulse Width | 300 - 900 micro second |
Leveraging on our skilled and qualified professionals, we are actively involved in offering a trendy range of Quadra TENS Biometric Instrument to our valuable customers at pocket-friendly prices.
Product Features:
Performance Specifications:
Output | Constant current. Output parameters stable over battery range |
Pulse Width Range | 300 to 900 microseconds |
Balance Range | 1:3 to 3:1 |
Channel Delay | 28 millisecond delay between channels to guarantee Zero Crossover between channels |
External Indicators | Green LED = normal mode (output on) Yellow |
LED flashing = stand-by (output off) | |
Red = Burst on (8 pulses at 800 Hz) | |
Controls | Balance control equalizes the right and left muscle responses. |
Amplitude dial with 1 to 9 range is used to set intensity | |
Power Source | A standard, disposable 9 volt battery. Long battery life : 100 hours of typical |
use with alkaline battery type. Rechargeable can be used with external charger. |